The end point of sublimation drying, or primary drying, is an important control point in the freeze drying process. Traditionally, the end of sublimation drying is determined by product temperature response, the rapid rise in product temperature after the temperature sensor loses thermal contact with ice being taken as evidence of the complete removal of ice from that container. However, the product temperature is measured by temperature sensors placed in a relatively small number of vials, and product in these vials can behave differently than the batch as a whole. There is clearly a need for an alternate method for end point detection which depends on a property of the batch as a whole. The partial pressure of water vapor in the drying chamber could serve as such a property. During sublimation drying, the partial pressure of water vapor in the drying chamber is high (close to the total pressure), but when the rapid evolution of water vapor ceases with the conclusion of sublimation drying, the partial pressure of water sharply decreases. In this research, an electronic moisture sensor is employed to monitor the partial pressure of water during the freeze drying process. The moisture sensor response provides a convenient and reliable method for determination of the end point of sublimation drying for the batch as a whole. The moisture sensor method has sufficient sensitivity to detect the presence of as few as 0.3% of the vials in a batch having residual ice. The moisture sensor method also provides a reliable determination of end point in several other applications where product temperature response is often not reliable, such as bulk freeze drying and freeze drying from very small containers.
- Received July 26, 1988.
- Accepted October 27, 1988.
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.