Abstract
The routes of airborne contamination, during Blow-Fill-Seal (BFS) production, were studied using tracer gas, particles and bacteria. The prevention of airborne contamination, by the air shower at the point of fill, was effective (>99.2% efficient). However, microbe-carrying particles could gain access, by deposition or air exchange, when the containers were cut open and before they shuttled under the protection of the air shower. The use of SF6 tracer gas demonstrated that when the air shower was not on, 50% of the air within the containers came from the area round the machine. When the air shower was switched on, only about 5% of the air came from the surroundings. Airborne microbial contamination of containers is in proportion to: the number of airborne microbes around the machine, the time the container is open, the neck area and the amount of air left within the container. The likely microbial contamination rate can be calculated from a model incorporating these variables. Microbial contamination of containers during BFS manufacturing is normally very low, but by increasing the naturally occurring bacteria in the air of the production rooms by about 100-fold, it was possible to verify the accuracy of this model. The contamination model agrees well with the observation that microbial contamination levels of between 1 in 105 and 1 in 107 will be found when small containers (<10 ml) are filled in conventionally ventilated rooms. To achieve similar contamination rates when filling of larger bottles, it is likely that unidirectional flow, or barrier technology will be required.
Footnotes
- Received December 13, 1996.
- Accepted November 26, 1997.
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.