Abstract
Glass prefillable syringes are lubricated with silicone oil to ensure functionality and a consistent injection for the end user. If excessive silicone is applied, droplets could potentially result in aggregation of sensitive biopharmaceuticals or clouding of the solution. Therefore, monitoring and optimization of the applied silicone layer is critical for prefilled syringe development. The hydrophobic properties of silicone oil, the potential for assay interference, and the very small quantities applied to prefilled syringes present a challenge for the development of a suitable assay. In this work we present a rapid and simple Fourier transform infrared (FTIR) spectroscopy method for quantitation of total silicone levels applied to prefilled syringes. Level-dependent silicone oil migration occurred over time for empty prefilled syringes stored tip-up. However, migration from all prefilled syringes with between 0.25 and 0.8 mg of initial silicone oil resulted in a stable limiting minimum level of between 0.15 and 0.26 mg of silicone in the syringe reached after 1 to 4 years of empty tip-up storage. The results of the FTIR assay correlated well with non-destructive reflectometry characterization of the syringes. This assay can provide valuable data for selection of a robust initial silicone oil target and quality control of prefilled syringes intended for biopharmaceuticals.
LAY ABSTRACT: Glass prefillable syringes are lubricated with silicone oil to ensure functionality and a consistent injection for the end user. If excessive silicone is applied, droplets could potentially result in aggregation of sensitive biopharmaceuticals or clouding of the solution. Therefore, monitoring and optimization of the applied silicone layer is critical for prefilled syringe development. The hydrophobic properties of silicone oil, the potential for assay interference, and the very small quantities applied to prefilled syringes present a challenge for the development of a suitable assay. In this work we present a rapid and simple Fourier transform infrared (FTIR) spectroscopy method for quantitation of total silicone levels applied to prefilled syringes. Level-dependent silicone oil migration occurred over time for empty prefilled syringes stored tip-up. However, migration from all prefilled syringes with between 0.25 and 0.8 mg of initial silicone oil resulted in a stable limiting minimum level of between 0.15 and 0.26 mg of silicone in the syringe reached after 1 to 4 years of empty tip-up storage. The results of the FTIR assay correlated well with non-destructive reflectometry characterization of the syringes. This assay can provide valuable data for selection of a robust initial silicone oil target and quality control of prefilled syringes intended for biopharmaceuticals.
- © PDA, Inc. 2014
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.