Abstract
Equilibration time of an autoclave is defined as the period of time that elapses between the attainment of sterilization temperature at the reference measurement point of the autoclave chamber and the attainment of sterilization temperature at all measurement probes within the dry goods load placed within the autoclave during a sterilization cycle. Equilibration time is an indicator of the ability of the autoclave to remove air from and subsequently sterilize the dry goods load placed within the autoclave chamber. Therefore equilibration time is an indicator of the efficacy of an autoclave cycle. Periodic measurements of equilibration time and evaluation of the equilibration time data can assure continued efficacy of the autoclave cycle. For autoclaves that support biopharmaceutical manufacturing plants, equilibration time is generally measured by placing heat penetration probes within dry goods load items placed within the autoclave during a sterilization cycle. However, equilibration time measured in this fashion yields results that are highly variable and difficult to replicate. This paper presents a study that attempts to understand the impact of the following autoclave variables on consistent measurement of equilibration time and reduction of equilibration time: 1. Type of dry good load item placed inside the autoclave 2. Location of the heat penetration probe placed within the dry good load item 3. Location of the dry good load item inside the autoclave chamber 4. Orientation of the dry good load item inside the autoclave chamber 5. Number of coils of the tubing elements of a dry good load item 6. Total thermal mass of the dry good load items placed inside the autoclave 7. Temperature of the dry good load items at the start of the sterilization cycle 8. Presence of residual moisture in the dry good load items at the start of sterilization cycle 9. Number of steam and vacuum pulses used for pre-conditioning in the autoclave recipe 10. Depth of steam and vacuum pulses used for pre-conditioning in the autoclave recipe 11. Hold time of steam and vacuum pulses used for pre-conditioning in the autoclave recipe The focus of this paper is on tests performed to evaluate these variables followed by analysis and interpretation of test data to identify key variables that have the highest impact on measurement of equilibration time. The conclusion of this paper presents a process to achieve shorter equilibration times in autoclaves through control of key variables identified.
- Received July 2, 2018.
- Accepted January 15, 2019.
- Copyright © 2019, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.