Abstract
Background: Flow Cytometry is a complex measurement characterisation technique, utilised within the manufacture, measurement and release of Cell and Gene Therapy products for rapid, high content and multiplexed discriminatory cell analysis. A number of factors influence the variability in the measurement reported including, but not limited to, biological variation, reagent variation, laser and optical configurations and data analysis methods. This research focuses on understanding the contribution of manual operator variability within the data analysis phase. Methods: 38 participants completed a questionnaire providing information about experience and motivational factors, before completing a simple gating study. Results were analysed using Gauge Repeatability & Reproducibility techniques to quantify participant uncertainty. The various stages of the gating sequence were combined through summation in quadrature and expanded to give each participant a representative uncertainty value. Results: 85 % of participants surveyed preferred manual gating to automated data analysis, with primary reasons being legacy (″it′s always been done that way″) and accuracy, not in the metrological sense, but in clear definition of the correct target population. The median expanded uncertainty was calculated as 3.6 % for the population studied, with no significant difference between more or less experienced users. Discussion: Operator subjectivity can be quantified to include within measurement uncertainty budgets, required for various standards and qualifications. An emphasis on biomanufacturing measurement terminology is needed to help understand future and potential solutions, possibly looking at translational clinical models to engage and enhance better training and protocols within industrial and research settings.
- Received November 19, 2019.
- Accepted September 14, 2020.
- Copyright © 2020, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.