Abstract
A previously unreported particle type was observed during routine visual vial inspection of a liquid drug product and suspected to be the result of vial delamination. Delamination is the corrosive attack on the interior surface of a glass container resulting in the release of thin flake-like glass particles, lamellae, into solution. It is a major concern for pharmaceutical companies, especially for parenteral solutions, and drug programs with a high risk for delamination are typically monitored for lamellae formation through long term stability studies. Although these particles observed resembled lamellae (i.e. thin, reflecting light, buoyant) they were not the result of glass delamination. In this study, the authors describe a previously unreported particle type and provide a detailed comparison to known lamellae exposed to the same drug formulation. The chemical, elemental, and morphological characteristics of the particles and respective vials are described in detail. Overall, the particles′ high organic and low silica elemental signature, along with no signs of delamination on the glass vial inner surface demonstrate that this lamellae-like observation is a novel particle form that can be distinguished from lamellae formed from via glass delamination.
- Received September 14, 2021.
- Accepted September 20, 2022.
- Copyright © 2022, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.