Abstract
Vial and syringe filling by peristaltic pump has been widely implemented by contract manufacturing organizations and biopharmaceutical companies. Fill volume is commonly considered as critical quality attribute related in aseptic filling process and the variation needs to be well controlled to guarantee the safety, efficacy and consistency of drug products. However, the criteria for justifying the filling variation and underlying mechanisms that affect the variability are not fully revealed quantitatively in the literatures. This study selected filling accuracy, filling process capability and filling precision as three criteria for evaluating the filling process performance with four statistical indexes: Relative Error Mean, Critical Control Limit (Cpk ≥ 1.33), Relative Standard Deviation and Relative Moving Range Mean. The impact of liquid properties, pump tubing sizes and pump settings on above indexes were investigated using a bench-top system with a peristatic pump and a high-precision balance. The results showed that the viscosity, target fill volume, pump tubing size, pump speed, acceleration/deceleration rate and suck-back had statistical significance on the fill volume variability. Definitive Screening Design was further applied to clarify and visualize the priorities and interaction impact of above factors on fill volume variability. Stepwise approach for fill volume variability optimization and control based on predictive models was established and verified for drug product solution with viscosity between 1-23 cp and target fill volume between 0.2-2.0 mL.
- Peristaltic pump
- fill volume variability
- filling accuracy
- filling accuracy optimization
- high concentration filling
- Received May 22, 2023.
- Accepted May 28, 2024.
- Copyright © 2024, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.