Abstract
An increasing number of pharmaceutical products require deep cold storage at cryogenic conditions, approximately -150°C to -190°C, to maintain stability and/or activity. Previous work has revealed that, at these extreme conditions, a typical pharmaceutical package configuration (vial, stopper, crimp cap) may lose container closure integrity (CCI) due to both the glass transition temperature (-55°C to -70°C) of the rubber stopper used to seal the vial and the different thermal expansion coefficients of the primary packaging components. Importantly, this type of temporary breach in CCI frequently reseals itself when the vial is brought back to ambient temperature. The following study illustrates a CCI test method for identifying both temporary and permanent defects in vial assemblies exposed to cryogenic storage conditions using laser-based headspace oxygen analysis. The method takes advantage of the nitrogen-enriched environment that exists in most cryogenic storage conditions. When vials are placed into cryogenic storage, the cold temperature creates a pressure gradient across the vial seal that, if a leak defect develops, drives nitrogen gas into the vial headspace and, thereby, decreases the headspace oxygen concentration for vials originally packaged with an air headspace. This decrease in headspace oxygen after the cryogenic storage period can be used to identify a breach in CCI, regardless of whether the defect is temporary or permanent. Experimental data obtained for three different vial types (a 2R glass vial, a 2 mL plastic CZ vial, and a 2 mL plastic Aseptic Technologies (AT) vial) demonstrated that this CCI test method can robustly and readily detect laser-drilled micron-sized positive controls down to 5 μm (the smallest defect size tested) in the body of the vial and type controls prepared using a Ø64 μm wire at the stopper-seal interface (effective defect size varied depending on the vial).
- Received December 5, 2022.
- Accepted October 29, 2024.
- Copyright © 2024, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.