Abstract
The detectability size threshold of visible particles (″visibility″ size) in the context of visual inspection of parenteral drug products has been an elusive target for several decades. The current common sense, also reflected in official guidelines, dictates that particles of different shapes and morphologies have different ″visibility″ size thresholds, that can range between hundreds and thousands of micrometers. This study demonstrates experimentally for the first time that it is possible to define a single, shape- and morphology- independent detectability size threshold, identical across particles of various types, provided that observation conditions and product attributes are kept constant. We propose that, based on the physiology of human visual perception, instead of single-dimension measures of particle size (e.g. diameter or length), such a single size-threshold requires the use of area-based size parameters (such as ″equivalent circular diameter″, or ECD. The experimental results reported here clearly demonstrate that the ″visibility″ thresholds for particles of various morphologies converge on a single ECD value. In addition, the data reported here show that product attributes, such as container configuration, fill volume etc. influence the threshold of visibility. Collectively, the findings reported in this paper provide substantial evidence and scientific rationale, as well as unanticipated prospects for standardization of visual inspection qualification practices, ultimately leading to improving pharmaceutical product quality.
- Knapp test
- equivalent circular diameter
- particle visibility limit
- threshold studies
- visible particles
- visual inspection
- Received June 24, 2024.
- Accepted December 17, 2024.
- Copyright © 2024, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.