Abstract
SVP in glass ampoules are manufactured using two main different technological production processes: the open-ampoule process (O) and the closed-ampoule process (C). In principle, the open-ampoule production technology should lead to better controlled production process. To test this hypothesis and quantify the possible qualitative differences in the manufactured ampoules, a suitable experimental design was set up. The two ampoule production processes have been compared on the basis of the visible particulate burden. Two batches of ampoules filled with water for injections were produced for each type of process, following conventional industrial procedures. Two samples of 20,000 units were taken from each batch and inspected with different automatic inspection systems: two Brevetti CEA machines (S1, S2—light scattering) and two EISAI machines (S3, S4—light absorbtion). The comparison between the processes was based on the rejection percentage. On both inspection machines the open-ampoule production samples present rejection percentages (ranging from 0.154% to 1.248% rejection percentages) which, on average, are lower than those detected in closed-ampoule production (ranging from 1.434% to 3.86% rejection percentages). The difference between the two processes is even more marked if we also consider the data obtained using inspection machines S3 and S4. The substantial differences in performance of the four inspection machines stress the need to provide for adequate validation procedures.
- Received October 2, 1992.
- Accepted March 18, 1993.
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.