Abstract
Fluorescence-coupled PCR technology was employed to quantify DNA segments specific for Staphylococcus aureus, Pseudomonas aeruginosa, and Enterobacteriaceae. The PCR procedure is put forward as an alternative method for detecting microbial contaminations in pharmaceutical preparations and is compared to the tests for specified microorganisms described in European Pharmacopoeia (EP) 2, 2.6.13 and the USP, chapter 61. Data presented here describe the validation of this analytical method when used for proof of absence of specified microorganisms. The detection systems were specific for the microorganisms analyzed, and led to linear results over a wide range (more than 6–7 log intervals). The correlation coefficients lay above 0.99. The precision of replicate determinations within a single test was observed to be high, the relative standard deviation being between 0.39% and 1.53%. The precision between different tests was also high, with a relative standard deviation between 0.76% and 1.91%. The sensitivity without pre-enrichment amounted to 1–10 CFU. Since determination of the specified bacteria was performed following pre-enrichment, the limit of detection amounted to 1 CFU. Equivalent results were obtained in a study on nine batches of a milky hydrophilic cream (SH-No. M 440 A) with the conventional test for microbial contamination and the PCR procedure. The data presented here strongly indicate that the use of fluorescence-coupled PCR techniques can prove the absence of specified bacteria faster and more efficiently than conventional methods.
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.