Abstract
The testing of the H2O2 decontamination process using spores of Bacillus stearothermophilus has gained widespread acceptance. Usually, commercially available Biological Indicators (BIs) with a specified resistance to H2O2 are challenged to qualify the process. The question arises whether the resistance of test spores is dependant on the type of carrier material and whether the resistance is representative for the system under test.
The objective of the study is to quantify the effect of different carrier materials on the resistance of spores of Bacillus stearothermophilus to H2O2. Materials from which isolators were built, as well as those used in disposables during daily work were investigated. These materials were inoculated with 106 spores of Bacillus stearothermophilus (ATCC 7953). The spore resistance was tested to a well defined H2O2 decontamination cycle by determining the D-value using the “Fractional Negative” method.
This paper reports on the effect of different carrier materials to the resistance of the test organism against H2O2. Various materials have significantly increased resistance of the spores and should be avoided in isolator systems. If commercially available BIs are used for process qualification, the resistance of the BI used, the fluctuation in resistance caused by isolator materials, the required log reduction, and at least the bioload of isolator surfaces need to be known.
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.