Inadequate cleaning of a pharmaceutical manufacturing plant or inadequate purging of the individual pieces of equipment used in multi-product manufacturing or equipment not dedicated to individual products may lead to contamination of the next batch of pharmaceutics manufactured using the same equipment. Challenges for cleaning validation are encountered especially when developing sensitive analytical methods capable of detecting traces of active pharmaceutical ingredients that are likely to remain on the surface of the pharmaceutical equipment after cleaning. A method's inability to detect some residuals could mean that either the method is not sensitive enough to the residue in question or the sampling procedure is inadequate.
A sensitive and reproducible reversed-phase, high-performance liquid chromatographic method was developed for the determination of ofloxacin in swab samples. The method for determining ofloxacin residues on manufacturing equipment surfaces was validated in regard to precision, linearity, accuracy, specificity, limit of quantification, and percent recovery from the equipment surface, as well as the stability of a potential contaminant in a cleaning validation process. The active compound was selectively quantified in a sample matrix and swab material in amounts as low as 0.55 ng/mL. The swabbing procedure using cotton swabs was validated. A mean recovery from stainless steel plate of close to 85% was obtained. Chromatography was carried out on a pre-packed Merck (Dermstadt, Germany) Lichrospher model 100 Rp-18 (5.0 μm, 250 mm × 4.0 mm) column using a mixture of sodium lauryl sulfate (0.024% aqueous solution), acetonitrile, and glacial acetic acid (500:480:20,v/v) as the mobile phase at a flow rate of 1.5 mL/min with a column temperature of 35 °C and 294 nm detection. The assay was linear over the concentration range of 2 ng/mL to 2000 ng/mL (R ≈ 0.99998). The method was validated for accuracy and precision. The stability of ofloxacin in the swab samples was also assessed. In regard to the 10-ppm acceptance criteria in the succeeding batch, the calculated limit was 437 μg/cm2 while according to the 0.1% dosing approach the calculated value was 116 μg/cm2. The calculated recovery values from swab samples were below these acceptable limits during three consecutive cleaning trials. This confirms that the desired level of cleanliness is achieved using the current cleaning procedures, which were consequently validated.
Footnotes
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.