Abstract
A sampler that detects and counts viable particles in the air of cleanrooms in real-time was studied. It was found that when the sampler was used to monitor airborne particles dispersed from a number of materials used in cleanrooms, including garments, gloves, and skin, the number of viable particles dispersed from these materials was greater than anticipated. It was concluded that a substantial proportion of these viables were of a non-microbiological origin. When the sampler was used to monitor a non-unidirectional airflow cleanroom occupied by personnel wearing cleanroom garments, it was found that the airborne viable concentrations were unrealistically high and variable in comparison to microbe-carrying particles simultaneously measured with efficient microbial air samplers. These results confirmed previously reported ones obtained from a different real-time sampler. When the real-time sampler was used in a workstation within the same cleanroom, the recorded viables gave results that suggest that the sampler may provide an effective airborne monitoring method, but more investigations are required.
LAY ABSTRACT: The airborne concentrations measured by a real-time microbial air sampler within an operational, non-unidirectional airflow cleanroom were found to be unrealistically high due to a substantial numbers of particles of non-microbiological origin. These particles, which resulted in false-positive microbial counts, were found to be associated with a number of materials used in cleanrooms. When the sampler was used within a cleanroom workstation, the counts appeared to be more realistic and suggest that this type of real-time airborne microbial counter may provide a useful monitoring method in such workstations, but further investigations are required.
- © PDA, Inc. 2014
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.