Abstract
The results of a proof-of-principle study demonstrating a new analytical technique for detecting microbial growth directly in pharmaceutical containers are described. This analytical technique, laser-based headspace analysis, uses tunable diode laser absorption spectroscopy to nondestructively determine gas concentrations in the headspace of a media-filled pharmaceutical container. For detecting microbial growth, the levels of headspace oxygen and carbon dioxide are measured. Once aerobic microorganisms begin to divide after the lag phase and enter the exponential growth phase, there will be significant consumption of oxygen and concomitant production of carbon dioxide in the sealed container. Laser-based headspace analysis can accurately measure these changes in the headspace gas composition. The carbon dioxide and oxygen measurement data for the representative microorganisms Staphylococcus aureus, Bacillus subtilis, Candida albicans, and Aspergillus brasiliensis were modeled using the Baranyi-Roberts equation. The mathematical modeling allowed quantitative comparisons to be made between the data from the different microorganisms as well as to the known growth curves based on microbial count. Because laser-based headspace analysis is noninvasive and can be automated to analyze the headspace of pharmaceutical containers at inspection speeds of several hundred containers per minute on-line, some potential new applications are enabled. These include replacing the current manual human visual inspection with an automated analytical inspection machine to determine microbial contamination of media fill and pharmaceutical drug product vials.
LAY ABSTRACT: A novel analytical technique has been demonstrated for detecting microbial growth in media-filled pharmaceutical containers. This analytical technique, laser-based headspace analysis, uses tunable diode laser absorption spectroscopy to determine gas concentrations in the headspace of a pharmaceutical container. For detecting microbial growth, the levels of headspace oxygen and carbon dioxide are measured. The study shows that once aerobic microorganisms begin to grow after the lag phase and enter the exponential growth phase there will be a significant consumption of oxygen in the sealed container as well as a corresponding production of carbon dioxide. Headspace analysis can accurately measure and monitor these changes in the headspace gas composition and could therefore be used to detect contaminated pharmaceutical containers. Because the technique can be automated to analyze hundreds of containers a minute on-line, there are opportunities for implementing a headspace inspection machine to perform automated inspection of media fills used to validate aseptic filling operations.
- Microbial detection
- Microbiological test method
- Media fill inspection
- Headspace analysis
- Headspace oxygen
- Headspace carbon dioxide
- Microbial growth
- Frequency modulation spectroscopy
- © PDA, Inc. 2016
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.