Nondestructive testing is a common method for root cause investigations of malfunction of mechanical devices, for example, medical devices for drug dose delivery. Radiography is a method that has the advantage that it is possible to see through the sample. In this work we are using neutron radiography to observe drug distribution in drug injection devices during the injection process and as post-injection examination. Using neutrons it is possible to show small amounts of liquid in capillaries, and foam bubbles are shown with great contrast compared to metal and glass. The investigation has two parts optimized for high spatial and high temporal resolution, respectively. Using high spatial resolution it is possible to resolve the thin films of drug product in foam and even to detect the drug residues in the injection needle. Switching to high temporal resolution we demonstrate that it is possible to follow the injection process. Spatio-temporal data sets of the injection process were acquired using remotely triggered injection devices and a camera allowing sub-second frame rates.
The motion analysis required the application of an edge-preserving spatio-temporal denoising filter to improve the signal-to-noise ratio. After filtering it is possible to detect relevant edges and extract motion curves from the spatio-temporal data.
LAY ABSTRACT: Neutron imaging is a nondestructive method based on radiography using neutrons and is suitable for detecting small amounts of aqueous liquids even in metallic casing/sheath/tubing. This property has here been used to visualize the distribution of a drug product in a syringe needle of a drug injection device. In the static case the method clearly showed the difference between needles that were empty, full, or contained a mix of gas and liquid. A second investigation was aimed to visualize the dynamic behavior of an auto-injector device. In this experiment the imaging method was capable of following the injection phase of the device. By analyzing the acquired images in time and space it is possible to measure the injection velocity curves of the piston and drug, respectively.
- © PDA, Inc. 2016
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.