Abstract
Gallium-68 radiolabeling is an increasingly common activity in radiopharmacy. Single vial cold kits to radiolabel DOTATOC and PSMA-11 with 68Ga were developed, either for manual or automated preparation. Both approaches are very specific and require aseptic compounding skills, raising the need for dedicated training. The aim of this work was to design and implement an integrative media-fill test (MFT) protocol inspired by 68Ga kit-based radiopharmaceuticals for operator qualification, suitable for both manual and automated preparation simulations. Three custom MFT protocols (two manual and one automated simulations) compatible with specific radiopharmacy equipment were designed for operator training. During MFT sessions, the microbiological quality of the working environment was monitored by surface and air sampling. The sensitivity of the tryptic soy broth (TSB) and the influence of the number of punctures performed in each vial on the units positivity were also studied. Four operators were evaluated and carried out in triplicate the three MFTs. None of the 336 incubated units showed turbidity, although 27.8% of surface samples and 11.1% of air samples were positive (1–4 CFU). Over 36 MFT sessions, 15 contaminations of the working area by TSB drops occurred. TSB sensitivity was estimated >3.12 UFC. Units positivity showed a probable relationship with the number of punctures in a vial and, more obviously, with the contamination level of the vial stopper. As a part of a general sterile compounding instruction, these MFT protocols may be useful tools for initial and continuing training of operators carrying out manual and automated 68Ga radiolabeling.
- Media-fill test
- Radiopharmacy
- Good radiopharmacy practices
- Sterile compounding
- 68Ga radiolabeling
- Operators qualification
- © PDA, Inc. 2022
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.