A validated bioassay is used to measure the potency of commercial lots, and as such, must be accurate, precise, and fit for its intended purpose. Regulatory guidelines for the validation of a bioassay include a characterization of features, such as accuracy, precision, linearity, and range. The journey of a validated bioassay typically starts in a development lab, where it may be eventually be qualified to measure the potency of clinical lots. Prior to validation, as the bioassay is transferred to new laboratories, the bioassay is studied and assessed across a series of small experiments. In this work, instead of considering each study as a separate, independent report, it is proposed that, beginning with the qualification study, the accuracy and precision of the bioassay be continuously characterized, with each subsequent study result building from the ones that preceded. We call this continuous qualification. Such a proposition is naturally carried out using Bayesian statistical methods in which the historical study data is used to construct prior knowledge that is blended with the current study data. By doing so, bioassay accuracy and precision may be assessed with high confidence well ahead of commercial manufacturing. Further, by following the total-variance approach, the method also allows for the construction of control limits for potency.
- Received November 7, 2019.
- Accepted July 20, 2020.
- Copyright © 2020, Parenteral Drug Association
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.