PT - JOURNAL ARTICLE AU - Gilberto Dalmaso AU - Anna Campanella AU - Paola Lazzeri TI - Continuous and Effective Microbiological Air Monitoring in Critical Environments: A Comparison of Analytical Methodologies AID - 10.5731/pdajpst.2019.010181 DP - 2020 Jul 01 TA - PDA Journal of Pharmaceutical Science and Technology PG - 446--455 VI - 74 IP - 4 4099 - http://journal.pda.org/content/74/4/446.short 4100 - http://journal.pda.org/content/74/4/446.full SO - PDA J Pharm Sci Technol2020 Jul 01; 74 AB - Manufacture of sterile products must strictly follow carefully established and validated analytical methods of manufacture and control. Based on this consideration, we evaluated scientific literature describing settle plates and active air sampler monitoring effectiveness. A contamination control strategy should be implemented by pharma manufacturers, especially for aseptic productions, to assess the effectiveness of environmental monitoring and demonstrate that the process is under statistical control. It is of key importance for microbiological monitoring data to correlate as best as possible with total particle monitoring data so that each batch release is reliably supported.