RT Journal Article SR Electronic T1 Microbial Growth in Small-Volume Pharmaceuticals JF PDA Journal of Pharmaceutical Science and Technology JO PDA J Pharm Sci Technol FD Parenteral Drug Association (PDA) SP 208 OP 212 VO 43 IS 5 A1 W. Whyte A1 L. Niven A1 N. D. S. Bell YR 1989 UL http://journal.pda.org/content/43/5/208.abstract AB The ability of aseptically filled pharmaceuticals to support microbial growth was tested on 43 small-volume products (mainly parenterals). These were inoculated with a variety of microorganisms which were known to be associated with contamination of pharmaceutical products. In general. Gram-negative bacteria were found to be much more likely to grow than Gram-positive. It was possible for an inoculum of a few cells to multiply to levels up to 107/mL. The presence of preservatives also influenced the likelihood of growth, 12 out of 19 (63%) of the pharmaceuticals without preservatives supporting growth of one or more microorganisms; only 3 out of 24 (12%) of those with preservatives supported growth. The importance of these observations is discussed with reference to formulation of aseptically filled products, environmental sampling and the quality of cleanroom conditions necessary for production. It is suggested that those pharmaceuticals which are designed to be sterile but not to be terminally sterilized, should be tested before production begins, for their ability to support microbial growth. In this way, the risks involved in aseptically filling can be ascertained. A test is proposed in which “indicator” microorganisms would predict the likelihood of pharmaceutical formulations supporting growth.