PT - JOURNAL ARTICLE AU - Aicholtz, Pat AU - Wilkins, Randy AU - Gabler, Raymond TI - Sterile Filtration Under Conditions of High Pressure and Bacterial Challenge Levels DP - 1987 Jul 01 TA - PDA Journal of Pharmaceutical Science and Technology PG - 117--120 VI - 41 IP - 4 4099 - http://journal.pda.org/content/41/4/117.short 4100 - http://journal.pda.org/content/41/4/117.full SO - PDA J Pharm Sci Technol1987 Jul 01; 41 AB - Experiments were performed to determine if sterilizing grade cartridge filters can retain bacteria under conditions of high challenge conditions and high pressure. In all cases the sterilizing grade filters, which passed the integrity test retained all bacteria even though the differential pressures exceeded the manufacturer’s recommended maximum continuous operating pressure. Under similar operating conditions 0.45 micron rated cartridges did not retain all bacteria.