RT Journal Article SR Electronic T1 Sterile Filtration Under Conditions of High Pressure and Bacterial Challenge Levels JF PDA Journal of Pharmaceutical Science and Technology JO PDA J Pharm Sci Technol FD Parenteral Drug Association (PDA) SP 117 OP 120 VO 41 IS 4 A1 Aicholtz, Pat A1 Wilkins, Randy A1 Gabler, Raymond YR 1987 UL http://journal.pda.org/content/41/4/117.abstract AB Experiments were performed to determine if sterilizing grade cartridge filters can retain bacteria under conditions of high challenge conditions and high pressure. In all cases the sterilizing grade filters, which passed the integrity test retained all bacteria even though the differential pressures exceeded the manufacturer’s recommended maximum continuous operating pressure. Under similar operating conditions 0.45 micron rated cartridges did not retain all bacteria.