PT - JOURNAL ARTICLE AU - Burrows, W. Dickinson AU - Nelson, James H. TI - IV Fluidmakers: Preparation of Sterile Water for Injection In a Field Setting DP - 1993 May 01 TA - PDA Journal of Pharmaceutical Science and Technology PG - 124--129 VI - 47 IP - 3 4099 - http://journal.pda.org/content/47/3/124.short 4100 - http://journal.pda.org/content/47/3/124.full SO - PDA J Pharm Sci Technol1993 May 01; 47 AB - Two approaches have been investigated for generating USP sterile, pyrogen-free water for injection (WFI) from potable water in the field. The first approach utilizes reverse osmosis (RO), ion exchange, a solid matrix filter containing activated carbon and zeta adsorbent, a final 0.2 μm pore size sterilizing filter and a device for transferring the WFI to an IV bag; prototype systems based on three different hand-operated RO units weigh 1.5–3.5 kg and are capable of producing WFI at rates of 1–10 L/hr. Parenteral solutions were made by adding WFI to an IV/bag containing concentrated Ringer’s lactate. The second approach, still in the breadboard stage, is similar but utilizes a larger ion exchange column in place of the RO unit and a multiport distribution head to fill a set of 18 1-L IV bags. This system, considered to be disposable, is capable of generating water of WFI quality at a fill rate of 0.5 L/min from a pressurized source.