Determination of HUV Based on Linear Regression Model for Vial and Disposable Syringe Configuration
Vial and Disposable Syringe Configuration | Determination of HUV from Linear Regression Model |
---|---|
2R vial and 1 mL disposable syringe | HUV (mL) = (0.00099*Viscosity) + 0.105 |
2R vial and 3 mL disposable syringe | HUV (mL) = (0.00077*Viscosity) + 0.097 |
6R vial and 5 mL disposable syringe | HUV (mL) = (0.001*Viscosity) + 0.174 |
10R vial and 10 mL disposable syringe | HUV (mL) = (0.00066*Viscosity) + 0.208 |