TABLE III

Results from an Attribute Gage Repeatability and Reproducibility Analysis Validating the Performance of the Visual Inspection Method for Black and Clear Particles ≥ 1000 μm in Size

Particle TypeParticle Size (µm)Nonconforming Accuracy Relative to StandardNonconforming Rated ConformingConforming Rated Nonconforming
Black30029%
50050%
1000100%0%3%
200092%8%3%
Clear30013%
50033%
100077%28%3%
200072%23%3%
Fiber100011%
200012%