TABLE VII

Extracted Trace Elements and Metals

ElementExtracted Amount,d μg/g
PVCRubberLDPEPolycarbonateCyclic Olefin
pH 2.5pH 9.5pH 2.5pH 9.5pH 2.5pH 9.5pH 2.5pH 9.5pH 2.5pH 9.5
Ca1.5NPc4.072.07NPcNPc6.60.800.811.7
Zn1.30.432.890.490.08NPc0.120.030.070.03
Br1.30.0817.520.50.400.081.10.070.540.02
Na0.60MEa3.05MEa0.96MEa1.0MEa0.96MEa
KMEaNPcMEa6.84MEaNPcMEaNPcMEaNPc
Fe0.350.150.330.08b0.12NPc0.710.060.24NPc
Mg0.260.213.502.900.180.04b0.240.170.160.15
Al0.14NPc0.663.560.09NPcNPcNPc0.07NPc
Cr0.02NPc0.010.01NPcNPc0.070.02NPcNPc
TiNPcNPc0.29NPcNPcNPcNPcNPcNPcNPc
Mn0.02NPc0.01NPc0.01NPcNPcNPcNPcNPc
SiNPcNPc0.100.25NPcNPcNPcNPcNPcNPc
Sr0.01b0.020.010.010.01NPcNPcNPcNPcNPc
NiNPcNPc0.010.01NPcNPcNPcNPcNPcNPc
CuNPc0.01NPcNPcNPcNPcNPcNPcNPcNPc
CoNPcNPcNPcNPc0.01NPcNPcNPcNPcNPc
V0.01NPc0.010.01NPcNPcNPcNPcNPcNPc
BaNP3NPcNPcNPcNPc0.01NPcNPcNPcNPc
As0.01NPcNPcNPcNPcNPcNPcNPcNPcNPc
Pb0.01bNPcNPcNPcNPcNPcNPcNPcNPcNPc
SbNPc0.01NPcNPcNPcNPcNPcNPcNPcNPc
MoNPc0.01NPcNPcNPcNPcNPcNPcNPcNPc
  • Notes:

  • a ME = this element a component of the extracting solution used and thus was not measurable as an extractable.

  • b Detected in only one of the two replicate extracts.

  • c NP = not present in this extract in measurable quantities.

  • d The reported value is the largest amount measured in either the sealed vessel or sonication extract.