HLVD Test Results for Pooled Negative Control Populations, at Lower and Upper Sensitivity Set Points
HVLD Test Method | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
High voltage set point (kV) | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 |
Sensitivity limit range | 275–285 | 255–265 | 250–260 | 240–250 | 255–265 | 240–250 |
Mean (V) | 2.95 | 2.96 | 2.76 | 2.84 | 2.82 | 2.85 |
Standard deviation (V) | 0.16 | 0.18 | 0.14 | 0.14 | 0.17 | 0.15 |
Coefficient of variation | 0.05 | 0.06 | 0.05 | 0.05 | 0.06 | 0.05 |
Count | 180 | 300 | 168 | 168 | 168 | 196 |
Mean ± 3 standard deviations (V) | 2.47–3.43 | 2.42–3.50 | 2.34–3.18 | 2.42–3.26 | 2.31–3.33 | 2.40–3.30 |