Table III

Summary of Drying Times for the mAb A Formulation Due to Interruption of Filling from Glass Nozzles as a Function of Suck-Back (SB) Settings

SB SettingDrying Time (min)
1.8 mm Glass Nozzle2.4 mm Glass Nozzle
0.7 m/s Airflow0.7 m/s Airflow0 m/s Airflow
0<10<15∼20
1<10∼15∼30
230–40∼90>120*
3<10∼15∼30
4<10∼15∼45
  • * No drying was observed before the end of the experiment.