Table III

The Results of Phase 3 Trials. The Results of Bacterial Challenge Tests of Three Different 0.2 μm Rated Penetration Control Filters with Three Batches of A. laidlawii Test Cells Generated Using the Selected Test Media

FilterStock Titer (CFU/mL)Flow Rate (mL/min)Influent Concentration (CFU/mL)Challenge/cm2Effluent Concentration (CFU/mL)LRV
Batch 1
11.8 × 10771.01.0 × 1061.5 × 1072.5 × 1050.6
21.8 × 10769.41.0 × 1061.5 × 1071.8 × 1041.7
31.8 × 107115.41.0 × 1061.5 × 1071.8 × 106BDL*
Batch 2
11.5 × 107115.42.9 × 1064.2 × 1072.7 × 1051.0
21.5 × 107200.02.9 × 1064.2 × 1072.2 × 1051.1
31.5 × 107117.62.9 × 1064.2 × 1073.7 × 1050.9
Batch 3
11.6 × 10793.01.5 × 1062.2 × 1075.9 × 1050.4
21.6 × 107117.61.5 × 1062.2 × 1073.4 × 1050.6
31.6 × 107144.61.5 × 1062.2 × 1071.0 × 1060.1
  • * BDL= below detection limit: Penetration was high and TR did not occur or was too low to be detected.