Table III

Airborne Viable and Microbiological Counts per 424.5 L (15ft3) When Cleanroom Undergarments and Full Cleanroom Attire were Worn

GarmentsAir Sampler Counts per 424.5 L (15ft3)
BioTrak®AndersenAirTrace®
ViablesGelatine FilterAerobic IncubationAnaerobic IncubationCombined MCPsAerobic Incubation
Cleanroom undergarments99022539942441357
Full cleanroom attire18810000
Times reduction of counts when full cleanroom attire compared to undergarments5.3225>399>42>441>357
Ratio of viables to combined MCPsCleanroom undergarments—990:441, or 2.3:1
Full cleanroom attire—188:0, or >188:1