Table V

The Impact of the Accumulative Caustic Exposure Time of the Cycled Resin on Quality Attributes (Residual Protein A and Viral Clearance Levels) and Performance Attributes (DBC and Yield) in a MAb-1 Case Study. Data provided by Al Magill and Daniel Bezila.

CycleCaustic Exposure Time (h)DBC (g/L)Yield (%)Residual Protein A (ng/mg)XMuLV ClearanceMVM Clearance
Reused Resin (LRV)Control Resin (LRV)Normalized LRV (%)Reused Resin (LRV)Control Resin (LRV)Normalized LRV (%)
1148
22927.6
332.93.778
441.92.190
5597
495390
505445
5155899.2
52562.73.090
53572.52.5100
545989
9910783
10010834
1011099612.5
1021113.63.3109
1031122.42.983
10411379
12413475
12513535
12613782
1271383.33.0110
1281392.92.9100
12914072
13014169
13114270
13214372
13314470
13414568
13514670
13614771
13714871
13815067
13915168
14015232
1411538516.6
1421542.62.796
1431552.12.0105