Table IV

Experimental Conditions for Determining Worst-Case Mixing Time and Assessing Worst-Case Mixing Impact on Drug Product Quality

MixerWorst-case Mixing Time (dye in 55% w/w sucrose solution)Mixing Impact on mAb A1 (with extended mixing time)
At low speedAt high speed
Mixing Speed (rpm)Volume (L)Mixing Time (min)Mixing Speed (rpm)Volume (L)Mixing Time (min)Mixing Speed (rpm)Volume (L)Mixing Time (min)
Magnetic Mixer10045<1100304801653060
LevMixer12845<1128304802103060
Mobius Mixer (50 L)240458524030480N/AN/AN/A
Mobius Mixer (50 L)4004522N/AN/AN/A4003060
  • N/A, not applicable.