RSF (N) of the Different CCS Configurations from Capping Equipment Setting 1 to 6. At Capping Equipment Setting 1 the RSF of the 3 mL Vials was Below the Detection Limit (error)
CCS Configuration | Capping Equipment Setting | |||||
---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | |
3 mL, serum, West cap | Error | 13.2 ± 2.2 | 37.1 ± 6.5 | 48.2 ± 5.9 | 75.3 ± 5.4 | 98.4 ± 7.0 |
3 mL, lyo, West cap | Error | 18.0 ± 2.4 | 38.0 ± 4.7 | 47.1 ± 7.0 | 71.8 ± 5.3 | 96.7 ± 7.4 |
15 mL, serum, Datwyler cap | 9.8 ± 1.6 | 18.0 ± 3.2 | 38.2 ± 4.3 | 51.0 ± 5.2 | 102.5 ± 8.0 | – |
15 mL, lyo, Datwyler cap | 12.7 ± 1.5 | 22.0 ± 3.2 | 45.3 ± 4.0 | 65.5 ± 6.4 | 105.6 ± 8.6 | – |
15 mL, serum, West cap | 14.1 ± 2.4 | 17.7 ± 2.5 | 37.7 ± 6.0 | 55.3 ± 7.3 | 91.3 ± 6.4 | – |
15 mL, lyo, West cap | 12.2 ± 3.1 | 19.9 ± 1.3 | 44.1 ± 4.5 | 53.5 ± 4.1 | 95.8 ± 13.3 | – |