TABLE I

Equivalent Lethality at Selected Time–Temperature Conditions

Lethality EquationLethality at 80 °C/20 min (1200 s)Lethality at 100 °C/5 minLethality at 121 °C/15 min
A01200 s30,000 s>11,000,000 s
B00.2 min5 min1888 min
F00.00158 min0.039 min15 min
  • Note: The values shown in each column represent the lethality reported using each of the different methods operating at identical time-temperature conditions.