TABLE VIII

Summary of Potential Cause of Protein Particulate Formation by Tight Clearance and/or Close Contact in Different Drug Product Processing Systems

Drug Product Processing SystemPresence of Tight Clearance (<5 mm)Presence of Close ContactSignificant Particle Formation
Top Mounted MixerNoNoNo
Magnetic MixerNoYesYes
Mavadrive™ MixerYesYesYes
LevMixer®Yes (3 mm)NoNo
Mobius® MixerYes (4 mm)NoNo
JetMixer™YesYesYes
Standard Stir Bar (SB1)YesYesYes
Stir Bar with Plastic Ring (SB2)YesYesYes
Stir Bar on Tri-Stand (SB3)Yes (<1 mm)YesYes
Top-Entry Stir Bar (SB4)NoNoNo
Rotary Piston PumpYes (<0.1 mm)YesYes
Double-Gap RheometerYes (0.4 mm)NoNo
Cone-Plate RheometerYes (0.01 mm at tip)NoNo
Parallel-Plate RheometerYes (0.10 mm)NoNo