Statistical Analysis of the Probability of Producing a Leaking Crack in Aluminosilicate and Conventional Borosilicate Vials for Bump Check and Lensing Crack Replication Methods, Based upon Values in Tables II and V
Method | Glass | 95% Two-Sided | ||||
---|---|---|---|---|---|---|
80% Two-Sided | ||||||
Median | ||||||
0.0250 | 0.1000 | 0.5000 | 0.9000 | 0.9750 | ||
Bump Check | Borosilicate | 0.1349 | 0.1577 | 0.2060 | 0.2607 | 0.2918 |
Aluminosilicate | <0.0003 | <0.0011 | <0.0069 | <0.0228 | <0.0362 | |
Lensing Crack | Borosilicate | 0.5751 | 0.6228 | 0.7086 | 0.7854 | 0.8214 |
Aluminosilicate | <0.0005 | <0.0021 | <0.0138 | <0.0450 | <0.0711 |
Both 80% and 95% two-sided confidence intervals are calculated, though the intervals reported for the aluminosilicate vials represent upper bounds due to the absence of failures.