TABLE IV

Potential Remediation Measures That May Be Taken on Detection of a Suspect Bioburden Event

• Apply a corrective sanitization using a more robust sanitization solution. MabSelect SuRe: 0.1–0.5 M NaOH; Prosep Ultra: 3% benzylalcohol (with 0.3% HCl). Acidification of the benzyl alcohol significantly improves the microbial kill kinetics, enabling effective sanitization.
• Some companies perform proactive sanitization with a stronger solution following high-impact activities (e.g., after packing and prior to each batch).
• Repeated sanitizations (e.g., three consecutive) may be more effective than a stronger solution in some cases.
• Physical removal may be more important to remove sporeformers (higher caustic levels may not be effective in in isolation).
• Increase the flush volume and sanitize in up- and down-flow mode.
• Empty columns can be passivated in response to detection of biofilm.
• Preventative maintenance procedures and soft part inspection frequency is enhanced.
• Manual cleaning of valves may be performed in difficult-to-clean locations.
• Separate sampling of gradient cart and column rinse water generally demonstrates the contamination location at column level.