TABLE I

Component and Dimensional Information of the Tubing Assembly Leading from the Surge Tank to the Filling Needles

ComponentFor 15 cm3 Vial (15 mL fill)For 20 cm3 Vial (21.4 mL fill)
FunctionMaterialID × WT (mm × mm)LengthHoldup Volume (mL)FunctionMaterialID × WT (mm × mm)LengthHoldup Volume (mL)
ATubingSilicone4.8 × 2.07213TubingSilicone6.0 × 2.17220.4
BTubingSilicone4.8 × 2.07213TubingSilicone6.0 × 2.17220.4
CTubingSilicone4.8 × 2.068.512.4TubingSilicone6.0 × 2.168.519.4
DConnection (male)Stainless SteelNANANAConnection (male)Stainless SteelNANANA
EY-ConnectionStainless SteelNANA4.5Y-ConnectionStainless SteelNANA7.8
FFitting to Y-Connection (female)PEEKNANANAFitting to Y-Connection (female)PEEKNANANA
Total volume from surge tank to needle (A+B+C+E)4368
  • ID, Inner diameter; NA, not applicable; WT, wall thickness.