TABLE II

Estimation of Moist Heat Resistance from Boil Test Results*

Exposure Time (min)Approximate D121°C-value (min)
10.01
100.1
200.2
1001.0
  • * The values in the table are only a mathematical approximation of survivor resistance at 121°C based upon conversion from the boil test temperature of 100°C.