TABLE I

Configurations of Vials and Statistical Data Generated from a Commercial Capper

ConfigurationVial Size (mL)Stopper Size (mm)Stopper TypeNumber of Vials MeasuredMean RSFa (N)RSD (%)Minimum (N)Maximum (N)Difference (N)
1213Serum143943.615.920.262.942.7
21520Serum114242.516.720.462.141.7
31520Lyophilization110453.214.726.877.450.6
42020Lyophilization134058.214.725.878.652.8
52020Lyophilization100050.312.724.766.841.1
62020Lyophilization100154.812.227.471.944.5
  • a RSF = residual seal force; RSD = relative standard deviation.