Start Conditions of Tests Performed for Item 1
Test # | Variable 6 | Variable 3 | Variable 4 | Variable 5 | Variable 7 (Average) |
---|---|---|---|---|---|
Test 1 | Maximum loading (36 items) | 36 zones in C1 and C2 | O1 | D1 | 54°C |
Test 2 | 33°C | ||||
Test 3 | 59°C | ||||
Test 4 | O2 | 24°C | |||
Test 5 | 24°C | ||||
Test 6 | 38°C | ||||
Test 7 | D2 | 36°C | |||
Test 8 | 20°C | ||||
Test 9 | 95°C | ||||
Test 10 | O1 | 22°C | |||
Test 11 | 93°C | ||||
Test 12 | 99°C | ||||
Test 13 | Minimum loading (1 item) | Zone 2 in C2 | O1 | D2 | 62°C |
Test 14 | Zone 2 in C2 | 41°C | |||
Test 15 | Zone 2 in C2 | 67°C |