Interference Fits for Stoppers Used in the Study
Theoretical Interference Fit | Range of Interference Limits (Min and Max) | |||||||
---|---|---|---|---|---|---|---|---|
Stopper | Plug Diameter (PD) | Vial Inner Neck Diameter (ID) | 1% | 2% | 3% | 5% | Actual% | (PDMIN−IDMAX) and (PDMAX− IDMIN) |
Stopper A with 25R vial EBB | 13.20 mm | 12.60 mm | 13.07 mm | 12.94 mm | 12.80 mm | 12.54 mm | ∼5% | 0.200 mm–1.000 mm |
Stopper B with 25R vial EBB | 13.20 mm | 12.60 mm | 13.07 mm | 12.94 mm | 12.80 mm | 12.54 mm | ∼5% | 0.200 mm–1.000 mm |