Investigation of a Filter Structure by Microbial Retention Studies: A Synthesis and Elaboration of Prior Findings

AM Trotter, TH Meltzer, F Bai… - PDA Journal of …, 2001 - journal.pda.org
Investigation of a Filter Structure by Microbial Retention Studies: A Synthesis and Elaboration of
Prior Findings | PDA Journal of Pharmaceutical Science and Technology Skip to main content …

The significance of sieve-retention to the filter validation process

TH Meltzer - PDA Journal of Pharmaceutical Science and …, 1995 - journal.pda.org
Current efforts at filter validation involve the need to test under “worst case conditions” the
bacterial retentive action of filters utilizing the very drug being processed. These concerns …

On the structural compatibilities of membrane filters

RC Lukaszewicz, TH Meltzer - PDA Journal of Pharmaceutical …, 1980 - journal.pda.org
Compatibility relationships between solid polymerics, such as membranes, and the liquids
they encounter reflect the similarity of their chemical bondings as defined by their cohesive …

Retention of Water-Borne Bacteria by Membrane Filters Part II: Scanning Electron Microscopy (SEM) and Fatty Acid Methyl Ester (FAME) Characterization of Bacterial …

S Sundaram, S Mallick, J Eisenhuth… - PDA Journal of …, 2001 - journal.pda.org
The results of scanning electron microscopic (SEM) and fatty acid methyl ester (FAME)
characterization of the bacterial species shown to penetrate conventional 0.2/0.22 μm rated …

[PDF][PDF] The sterilizing filter and its pore size rating

TH Meltzer, MW Jornitz - American Pharmaceutical Review, 2003 - researchgate.net
Filtration is a useful separation technique for the removal of par-ticles from fluid
suspensions. Sterile filtration constitutes an important application whereby liquid drug …

The importance of accurate microorganism identification in microbial challenge tests of membrane filters—Part I

I Kaesler, G Haake, H Hennig… - PDA Journal of …, 2011 - journal.pda.org
Microbial challenge testing is a common procedure to determine the retention efficiency,
performance, and validity of a sterilizing-grade filter. The ASTM 838-05 standard describes a …

[CITATION][C] Disposable filter devices

T Loewe, M Dixit - Single‐Use Technology in …, 2010 - Wiley Online Library
Disposable Filter Devices Page 1 Disposable Filter Devices 11.1 11.2 11.3 11.4 11.5
Introduction Filtration—Operating Principles 11.2.1 Dead-end filtration 11.2.2 CF Filtration …

Application of membrane filtration for removal of diminutive bioburden organisms in pharmaceutical products and processes

S Sundaram, M Auriemma, G Howard… - PDA Journal of …, 1999 - journal.pda.org
In this report, we present results of a recent investigation in our laboratories demonstrated
the effect of process conditions and/or drug product composition on the ability of 0.2 μm and …

[PDF][PDF] Relative efficiencies of double filters or tighter filters for small-organism removals

TH Meltzer, MW Jornitz… - Pharmaceutical technology, 1999 - researchgate.net
(6). Concerns about viable but nonculturable organisms are also increasing (7). In these
circumstances, some researchers argue for the use of tighter filters, namely 0.1-m rated …

[CITATION][C] Microbiological methods for quality control of membrane filters

FW Bowman, MP Calhoun… - Journal of pharmaceutical …, 1967 - Wiley Online Library
Microbiological methods for quality control of membrane filters Page 1 Microbiological Methods
for Quality Control of Membrane Filters By FRANCES W. BOWMAN, MIRIAM P. CALHOUN …