Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
OtherResearch

Evaluation of extreme depyrogenation conditions on the surface hydrolytic resistance of glass containers for pharmaceutical use

Massimo Guglielmi, Satoshi Arai, Peggy Georges, Amy Meisner, Peter Otton, Serena Panighello, Volker Rupertus, Jingwei Zhang and Daniele Zuccato
PDA Journal of Pharmaceutical Science and Technology November 2024, pdajpst.2024.012972; DOI: https://doi.org/10.5731/pdajpst.2024.012972
Massimo Guglielmi
1 University of Padova;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: massimo.guglielmi@unipd.it
Satoshi Arai
2 Nippon Electric Glass Co.;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: sarai@neg.co.jp
Peggy Georges
3 Corning European Technology Center;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: georgesp@corning.com
Amy Meisner
4 Glass Technology Services Ltd;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: a.meisner@glass-ts.com
Peter Otton
5 Nipro Pharma Packaging Americas Corporation;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: peter.otto@nipro-group.com
Serena Panighello
6 Stevanato Group - Nuova Ompi;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: serena.panighello@stevanatogroup.com
Volker Rupertus
7 SCHOTT AG;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: volker.rupertus@schott.com
Jingwei Zhang
8 SGD Group;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: jingwei.zhang@sgdgroup.com
Daniele Zuccato
9 Schott AG
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: daniele.zuccato@schott.com
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

This paper is the result of a round robin activity run by the Technical Committee TC12, Pharma Packaging, of the International Commission on Glass (ICG). The study was motivated by a concern about the risk that the depyrogenation treatment of glass vials, when performed in an abnormal way that deviates from the usual procedure, may have a negative impact on the hydrolytic resistance of the container inner surface. The study was executed by using 10 ml clear type I Borosilicate glass vials representing four different compositions. For the applied depyrogenation process extreme parameters were chosen to with maximum temperature up to 400°C, exposure times up to 72 hours and different amounts of residual water inside as starting conditions. Those treated samples were tested in seven different laboratories as a round robin test.. A large amount of data was obtained, which clearly indicate that the hydrolytic resistance performance of the Type I Borosilicate glass vials is not affected even by such extreme depyrogenation conditions (e.g. 400°C, 72hours and not perfect dried inside). This is an important and useful result, both for glass and pharma companies, based on the 12.000 analytical data collected during the interlaboratory activity.

  • Depyrogenation
  • Glass vials
  • Hydrolytic resistance
  • ICP-OES
  • Round robin test
  • Type I borosilicate glass
  • Received May 17, 2024.
  • Accepted November 15, 2024.
  • Copyright © 2024, Parenteral Drug Association

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 79 (2)
PDA Journal of Pharmaceutical Science and Technology
Vol. 79, Issue 2
March/April 2025
  • Table of Contents
  • Index by Author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Evaluation of extreme depyrogenation conditions on the surface hydrolytic resistance of glass containers for pharmaceutical use
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
18 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Evaluation of extreme depyrogenation conditions on the surface hydrolytic resistance of glass containers for pharmaceutical use
Massimo Guglielmi, Satoshi Arai, Peggy Georges, Amy Meisner, Peter Otton, Serena Panighello, Volker Rupertus, Jingwei Zhang, Daniele Zuccato
PDA Journal of Pharmaceutical Science and Technology Nov 2024, pdajpst.2024.012972; DOI: 10.5731/pdajpst.2024.012972

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Evaluation of extreme depyrogenation conditions on the surface hydrolytic resistance of glass containers for pharmaceutical use
Massimo Guglielmi, Satoshi Arai, Peggy Georges, Amy Meisner, Peter Otton, Serena Panighello, Volker Rupertus, Jingwei Zhang, Daniele Zuccato
PDA Journal of Pharmaceutical Science and Technology Nov 2024, pdajpst.2024.012972; DOI: 10.5731/pdajpst.2024.012972
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • A Holistic Approach for Filling Volume Variability Evaluation and Control with Statistical Tool
  • A Proof-of-Concept Study on a Universal Standard Kit to Evaluate the Risks of Inspectors for Their Foundational Ability of Visual Inspection of Injectable Drug Products
Show more Research

Similar Articles

Keywords

  • Depyrogenation
  • Glass vials
  • Hydrolytic resistance
  • ICP-OES
  • Round robin test
  • Type I borosilicate glass

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire