Skip to main content
  • Main menu
  • User menu
  • Search

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
OtherResearch

A proof-of-concept study on a universal standard kit to evaluate the risks of inspectors for their foundational ability of visual inspection of injectable drug products

Hirohito Katayama, Manabu Tsuda, Yukari Koga, Nobuaki Habasaki, Kosuke Taniyama, Yuichi Minato, Akihiro Oda, Kouichi Nagata, Takashi Amagasa and Kimitaka Misawa
PDA Journal of Pharmaceutical Science and Technology March 2025, pdajpst.2023.012911; DOI: https://doi.org/10.5731/pdajpst.2023.012911
Hirohito Katayama
1 CM Plus Corporation;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: katayama@cm-plus.co.jp
Manabu Tsuda
2 Mitsubishi Tanabe Pharma Corporation;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: tsuda.manabu@md.mt-pharma.co.jp
Yukari Koga
3 Kyowa Kirin Co. Ltd.;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: yukari.koga.p1@kyowakirin.com
Nobuaki Habasaki
4 Idorsia Pharmaceuticals Ltd;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: nhabasaki@gmail.com
Kosuke Taniyama
5 Cytiva;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: kosuke_taniyama@ap.pall.com
Yuichi Minato
3 Kyowa Kirin Co. Ltd.;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: yuichi.minato.qj@kyowakirin.com
Akihiro Oda
6 Namicos Corporation;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: akihiro-oda@namicos.co.jp
Kouichi Nagata
6 Namicos Corporation;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: kouichi-nagata@namicos.co.jp
Takashi Amagasa
7 Terumo Co. Ltd;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: takashi_amagasa@terumo.co.jp
Kimitaka Misawa
8 Shionogi Pharma Co. Ltd.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: kimitaka.misawa@shionogi.co.jp
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Visual inspectors′ ability to detect foreign matter in injections must be qualified for each product type or bracketing group, as stated in the United States Pharmacopeia <1790>. The common defect criterion is ″visible″ However, this qualitative lower rejection limit is based on the premise that the nature of human inspection at one site is globally comparable to that at all other sites. If not, the ″visible″ foreign matter can vary among inspector groups for each product, leading to quality differences between sites. Inspectors are trained and qualified using ″visible″ foreign matter samples from their site; therefore, inspectors′ ability to detect foreign matter can differ due to different standards. Japanese pharmaceutical companies import injections and perform secondary visual inspections because variations in ″visible″ ability arise due to individual differences among regions. Currently, there is no universal method for comparing ″visible″ rejection zones among manufacturing sites for different products because product-specific standard samples for qualifications cannot be universalized. Therefore, instead of comparing the product-specific ″visible″ standard sample, this study proposes a novel universal particle standard challenge kit to compare sites' or inspectors' inner ″visible″ detection ability. Our results suggest that the proposed kit could evaluate the comparability of ″visible″ at each site and for each inspector but not on sites′ ″visible″ standard samples. The primary challenge in implementing a universal standard lies in the inherent bias of inspectors already acclimated to specific products. This study found that an inspectors′ foundational ability can be evaluated by canceling the bias via rapid and effective training in cases of simple standard samples. Our results suggest that using a universal standard kit to assess an inspector′s fundamental ability to detect ″visible″ foreign matter is feasible. The study does not aim to replace the inspectors′ product qualifications but to compare their inner ability for risk assessment.

  • comparability
  • foreign matter
  • foundational ability
  • human inspector
  • universal standard
  • visual inspection
  • Received October 15, 2023.
  • Accepted March 5, 2025.
  • Copyright © 2025, Parenteral Drug Association

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 79 (3)
PDA Journal of Pharmaceutical Science and Technology
Vol. 79, Issue 3
May/June 2025
  • Table of Contents
  • Index by Author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Email Article
Citation Tools
Share
A proof-of-concept study on a universal standard kit to evaluate the risks of inspectors for their foundational ability of visual inspection of injectable drug products
Hirohito Katayama, Manabu Tsuda, Yukari Koga, Nobuaki Habasaki, Kosuke Taniyama, Yuichi Minato, Akihiro Oda, Kouichi Nagata, Takashi Amagasa, Kimitaka Misawa
PDA Journal of Pharmaceutical Science and Technology Mar 2025, pdajpst.2023.012911; DOI: 10.5731/pdajpst.2023.012911
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Analysis of Virus Clearance for Biotechnology Manufacturing Processes from Early to Late Phase Development
  • Coring and Fragmentation of Elastomeric Needle Shield in a Pre-Filled Syringe
  • Worldwide Regulatory Reliance: Results of an Executed Chemistry, Manufacturing, and Control Post-Approval Change Pilot
Show more Research

Similar Articles

Keywords

  • comparability
  • foreign matter
  • foundational ability
  • human inspector
  • universal standard
  • Visual inspection

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire
Alerts for this Article
Sign In to Email Alerts with your Email Address
Email this Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A proof-of-concept study on a universal standard kit to evaluate the risks of inspectors for their foundational ability of visual inspection of injectable drug products
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
1 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
A proof-of-concept study on a universal standard kit to evaluate the risks of inspectors for their foundational ability of visual inspection of injectable drug products
Hirohito Katayama, Manabu Tsuda, Yukari Koga, Nobuaki Habasaki, Kosuke Taniyama, Yuichi Minato, Akihiro Oda, Kouichi Nagata, Takashi Amagasa, Kimitaka Misawa
PDA Journal of Pharmaceutical Science and Technology Mar 2025, pdajpst.2023.012911; DOI: 10.5731/pdajpst.2023.012911

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero

We use cookies on this site to enhance your user experience

By clicking any link on this page you are giving your consent for us to set cookies.