Skip to main content

Main menu

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
PDA Journal of Pharmaceutical Science and Technology
  • .
    • Visit PDA
    • PDA Letter
    • Technical Reports
    • news uPDATe
    • Bookstore
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
PDA Journal of Pharmaceutical Science and Technology

Advanced Search

  • Home
  • Content
    • Current Issue
    • Past Issues
    • Accepted Articles
    • Email Alerts
    • RSS
    • Terms of Use
  • About PDA JPST
    • JPST Editors and Editorial Board
    • About/Vision/Mission
    • Paper of the Year
  • Author & Reviewer Resources
    • Author Resources / Submit
    • Reviewer Resources
  • JPST Access and Subscriptions
    • PDA Members
    • Institutional Subscriptions
    • Nonmember Access
  • Support
    • Join PDA
    • Contact
    • Feedback
    • Advertising
    • CiteTrack
  • Follow pda on Twitter
  • Visit PDA on LinkedIn
  • Visit pda on Facebook
OtherCommentary

Standardization of Chromatographic Screening Methods for Organic Extractables and Leachables by Managing Outcomes

Dennis Jenke
PDA Journal of Pharmaceutical Science and Technology March 2023, pdajpst.2021.012671; DOI: https://doi.org/10.5731/pdajpst.2021.012671
Dennis Jenke
Triad Scientific Solutions
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: dennisjenke@triadscientificsolutions.com
  • Article
  • References
  • Info & Metrics
  • PDF
Loading

Abstract

Drug products and medical devices can contain impurities, termed leachables, which could produce an adverse patient health effect during clinical use. To establish patient exposure to leachables, drug products, packaging or manufacturing system extracts are analytically screened for extractables or leachables. Similarly, medical device contact media or extracts are also screened for extractables or leachables. Considering organic extractables/leachables, the screening process typically involves a chromatographic separation coupled with an information-rich detection method. Information contained in the detector response (e.g., the chromatographic peak) is processed to establish quantities and to elucidate identities. Organic extractables and leachables screening methods and procedures have proliferated with little, if any, attempt at standardization, creating the situation where virtually every testing laboratory has their own analytical testing and data processing methodology, raising the possibility that two different labs, screening the same extract or drug product, would report extractables or leachables profiles that differ in the number of compounds reported, the identities of the reported compounds and the extracted (or leached) amounts of the identified compounds. Although standardization of the screening methods and procedures themselves would reduce lab-to-lab variation, such an approach would be difficult to implement. Thus, standardization of the screening outputs by setting quality standards for the outputs is considered. For example, the method′s ability to detect a broad cross-section of potential extractables/leachables is established by testing of a test mixture of representative compounds. Additionally, this author proposes that reported compound identities should be confident to be used in safety risk assessment; use of lower quality identities requires use of an uncertainty factor in the safety risk assessment. Similarly, it is proposed that reported concentrations should be semi-quantitative to be used in safety risk assessment; use of lower quality concentrations requires use of an uncertainty factor in the safety risk assessment.

  • extractables
  • identification
  • leachables
  • quantitation
  • screening
  • standardization
  • Received July 15, 2021.
  • Accepted March 21, 2023.
  • Copyright © 2023, Parenteral Drug Association

PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.  

If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing. 

Full issue PDFs are for PDA members only.

Note to pda.org users

The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.

Log in using your username and password

Forgot your user name or password?

Log in through your institution

You may be able to gain access using your login credentials for your institution. Contact your library if you do not have a username and password.
If your organization uses OpenAthens, you can log in using your OpenAthens username and password. To check if your institution is supported, please see this list. Contact your library for more details.

Purchase access

You may purchase access to this article. This will require you to create an account if you don't already have one.

patientACCESS

patientACCESS - Patients desiring access to articles

Full issue PDFs are for PDA members only. You can join PDA at www.pda.org. 

PreviousNext
Back to top

In This Issue

PDA Journal of Pharmaceutical Science and Technology: 79 (1)
PDA Journal of Pharmaceutical Science and Technology
Vol. 79, Issue 1
January/February 2025
  • Table of Contents
  • Index by Author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on PDA Journal of Pharmaceutical Science and Technology.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Standardization of Chromatographic Screening Methods for Organic Extractables and Leachables by Managing Outcomes
(Your Name) has sent you a message from PDA Journal of Pharmaceutical Science and Technology
(Your Name) thought you would like to see the PDA Journal of Pharmaceutical Science and Technology web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
9 + 8 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Standardization of Chromatographic Screening Methods for Organic Extractables and Leachables by Managing Outcomes
Dennis Jenke
PDA Journal of Pharmaceutical Science and Technology Mar 2023, pdajpst.2021.012671; DOI: 10.5731/pdajpst.2021.012671

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Standardization of Chromatographic Screening Methods for Organic Extractables and Leachables by Managing Outcomes
Dennis Jenke
PDA Journal of Pharmaceutical Science and Technology Mar 2023, pdajpst.2021.012671; DOI: 10.5731/pdajpst.2021.012671
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
  • References
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Understanding Alignment in the Execution of Extractable Screening Studies Between Laboratories: Results of the ELSIE Lab Practices Sub-Team Industry Surveys
  • Accurate or Protective: What Is the Goal of Non-Targeted Extractables and Leachables Quantitation and Identification?
  • Google Scholar

More in this TOC Section

  • Retrospective Evaluation of Cycled Resin in Viral Clearance Studies - A Multiple Company Collaboration - Post ICH Q5A(R2) Review
  • Expanding the Use of Moist Heat for Terminal Sterilization
  • Addressing Medical Device Extractables and Leachables via Non-Target Analysis (NTA); The Analytical Evaluation Threshold (AET) and Quantitation
Show more Commentary

Similar Articles

Keywords

  • Extractables
  • Identification
  • Leachables
  • Quantitation
  • Screening
  • Standardization

Readers

  • About
  • Table of Content Alerts/Other Alerts
  • Subscriptions
  • Terms of Use
  • Contact Editors

Author/Reviewer Information

  • Author Resources
  • Submit Manuscript
  • Reviewers
  • Contact Editors

Parenteral Drug Association, Inc.

  • About
  • Advertising/Sponsorships
  • Events
  • PDA Bookstore
  • Press Releases

© 2025 PDA Journal of Pharmaceutical Science and Technology Print ISSN: 1079-7440  Digital ISSN: 1948-2124

Powered by HighWire