Abstract
Filter manufacturers characterize a given filter type by a single acceptable maximum diffusive air flow level. A too high value is prudently rejected as signalling the possible presence of flaws. Values lower than the stipulated maximum are accepted. However, the presence of single pores, whatever their sizes, is not being revealed. Only their influence within the total porosity is measured by the diffusive airflow. Single point diffusive airflow integrity testing may invite misleading conclusions because it offers possibilities for lower airflows to mask the presence of flaws or of outsized pores. This is particularly so where initial (prefiltration) and final integrity are being compared. The filtrative accretion of retained material, viable or not, must inevitably come to block or diminish the size of the pores. This results in decreased total porosity, directly expressed in lower diffusive airflow values. Sufficient drop in such final air flow values may mask the presence of a flaw developed in the filter subsequent to its initial testing. For this reason a filter’s entire airflow permeation curve, particularly including its bubble point, must be characterized. It is this measurement, and this measurement alone, that is capable of unambiguously revealing the existence of insufficiently retentive pores. The inquiry into such presences is the very purpose of filter integrity testing.
- Received January 8, 1991.
- Accepted September 19, 1991.
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.