Abstract
The prerequisites for estimating the effect of signal coincidence on both particle undercounting and the injection of false counts in the implementation of U.S.P. 788 contaminating particle assays by light extinction particle counters are defined. These include a particle concentration measure that varies with particle size and a new model of the counting process. Both prerequisites have been verified empirically: a single normalized equation describes the coincidence effect in all single particle counters. The single parameter of the normalized equation is the number of effective detector volumes per milliliter. A maximum undercount limit of 5% is proposed based on adequately suspended particles. Using the SVP U.S.P. XXII acceptance limits of 10,000 particles per container or the PMA propose 6,000 particles per container maximum for particles >10 µm in U.S.P. XXIII, undercount errors are estimated for the smallest container sizes. The large concentration of particles below the controlled 10 µm particle size, that has been documented in injectable solutions, can pose an additional 788 measurement hazard. A Poisson model is used to estimate and control the injection of false particle counts into the mandated measurement through particle coincidence. Acceptable counting accuracy limits with present particle counting systems can be achieved by understanding the capabilities of the particle counter measurement system and using a dilution technique when appropriate. The new model of the counting process and the new particle concentration measures can result in standard, conservative, instrument specifications for use in Pharmacopeial contamination testing and in GLP user evaluation tests. Part I of this paper includes the theory of the coincidence effect on particle counting and the particle size distribution measured. A summary of the experimental verification employed to determine coincidence count loss as a function of particle concentration for single particle counters is reported. Part II of this paper describes a practical protocol for the determination of operating limits to achieve a selected coincidence undercount limit for single particle counters.
- Copyright © Journal of Pharmaceutical Science and Technology(JPST). All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.