Abstract
We present, in detail, the (microbiological) environmental monitoring programme for cleanrooms that is in use at the RIVM†. The parameters that are measured are: Total airborne particles of 0.5 μm and larger, airborne colony forming units (cfu’s), cfu’s on surfaces, cfu’s on fingertips of gloves and settling cfu’s. Most attention is paid to areas where critical handling is performed (class A areas). In these areas sampling is performed continuously during work. The areas surrounding class A areas are seen as a necessary environment to create a class A area and are called supporting areas. Changes in these supporting areas that will adversely effect the quality of the class A area, will be detected in the continuous sampling of the class A area. Sampling the supporting areas should only bring forward whether the measured parameters of these areas are consistent. The frequency of sampling, either weekly, monthly or three monthly, is based on the data obtained in previous sampling. In addition to the programme some data are presented. These data indicate that the values of the earlier mentioned parameters are not particularly dependent upon the lay–out or classification of areas, but rather on the use of the areas, and how the operators behave in them. The results support the concept of our sampling schedule, that relevant information about the production areas can be gathered with relatively little effort. Evaluating the programme, we conclude that the main missing element is a known relation between the results of environmental monitoring and contamination of products. We strongly advocate research that could result in establishing such a relation.
- Received December 22, 1995.
- Accepted August 22, 1996.
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.