Abstract
The results of bacterial challenge tests conducted on several 0.2 and 0.22 μm rated “sterilizing grade” filter cartridge types with bacteria from a natural water source are presented. Eight different 0.2/0.22 μm rated “sterilizing grade” filter types from four different filter manufacturers, claimed to be capable of retaining Brevundimonas diminuta at a challenge level of 107 CFU/cm2, were tested. The filters tested included nylon 6,6 and polyamide filters from two manufacturers, modified or hydrophilic PVDF filters from two manufacturers, modified or asymmetric PES filters from three manufacturers, and cellulose acetate filters from a single manufacturer. Consistent bacterial penetration was observed, over the 18–24 h challenge period, for all twenty-five integral 0.2 and 0.22 μm rated filter cartridges tested, at challenge levels of about 101-104 CFU/cm2, indicating that natural waterborne bacteria were more penetrative than B. diminuta. The observed penetration was thus qualitatively independent of filter media type or manufacturer. These results add to the growing body of evidence that shows 0.2 and 0.22 μm rated filters may not remove all microorganisms under all conditions. These results further establish that bacterial penetration of 0.2/0.22 μm rated filters is not limited just to (1) specific membrane types, or (2) extended duration challenges (≫ 24 h), or (3) extremely high challenge levels, or (4) bacteria that can only exist in a penetrative state in an artificial laboratory setting.
Footnotes
↵1Current affiliation: Immuno-Rx, New York
- Copyright © Parenteral Drug Association. All rights reserved.
PDA members receive access to all articles published in the current year and previous volume year. Institutional subscribers received access to all content. Log in below to receive access to this article if you are either of these.
If you are neither or you are a PDA member trying to access an article outside of your membership license, then you must purchase access to this article (below). If you do not have a username or password for JPST, you will be required to create an account prior to purchasing.
Full issue PDFs are for PDA members only.
Note to pda.org users
The PDA and PDA bookstore websites (www.pda.org and www.pda.org/bookstore) are separate websites from the PDA JPST website. When you first join PDA, your initial UserID and Password are sent to HighWirePress to create your PDA JPST account. Subsequent UserrID and Password changes required at the PDA websites will not pass on to PDA JPST and vice versa. If you forget your PDA JPST UserID and/or Password, you can request help to retrieve UserID and reset Password below.